Raid 5 Recovery

RAID 5 Data Recovery

No Fix - No Fee!

Our experts have extensive experience recovering data from RAID servers. With 25 years experience in the data recovery industry, we can help you securely recover your data.
Raid 5 Recovery

Software Fault From £495

2-4 Days

Mechanical FaultFrom £895

2-4 Days

Critical Service From £995

1-2 Days

Need help recovering your data?

Call us on 02890 961976 or use the form below to make an enquiry.
Chat with us
Monday-Friday: 9am-6pm

Raid 5 Recovery Services

RAID 5 (Redundant Array of Independent Disks) is one of the most widely used RAID configurations because it combines data redundancy with performance improvements. RAID 5 uses data striping with parity, allowing the array to continue functioning even if one drive fails. However, if multiple drives fail or there is corruption in the array, data loss can occur. Our Professional RAID 5 recovery and repair services are often required to recover data from a failed RAID 5 array.

The details below will explain how RAID 5 works, the common causes of RAID 5 failures and how we can recover Raid 5 Array data as we have 25 years experience.

Understanding RAID 5: How It Works

RAID 5 uses striping (distributing data across multiple drives) along with parity, which provides redundancy. Parity information is distributed across all drives in the array, allowing the array to reconstruct data from a failed drive using the remaining drives and the parity data.

  • Data Striping with Parity: RAID 5 stripes data across all drives and stores parity information that allows for data reconstruction if one drive fails.
  • Redundancy for One Drive: RAID 5 can tolerate the failure of one drive without data loss. However, if more than one drive fails, the entire array is at risk.
  • Balance of Performance and Redundancy: RAID 5 offers a good balance of performance and fault tolerance, making it popular in both business and personal storage systems.

Common Causes of RAID 5 Failure

Even though RAID 5 provides redundancy, it can still fail due to various hardware or logical issues. Here are the most common causes of RAID 5 failures:

1. Multiple Drive Failures

RAID 5 can tolerate a single drive failure, but if a second drive fails before the array is rebuilt, data becomes inaccessible, and recovery becomes complex.

  • Symptoms: The array goes offline, multiple drives show as “failed” or “degraded,” the system won’t boot, or data becomes inaccessible.
  • Causes: Mechanical wear, power surges, overheating, or multiple drive failures within a short period.
  • Drives Affected: Any hard drive or SSD in the RAID 5 array.

2. RAID Rebuild Failure

When a failed drive in a RAID 5 array is replaced, the RAID controller starts a rebuild process to restore the array using the parity data. If this rebuild fails, the data on the array can be lost or corrupted.

  • Symptoms: Incomplete RAID rebuilds, array degradation, data corruption, or slow access times.
  • Causes: Power loss during the rebuild, RAID controller failure, or hardware issues.
  • Drives Affected: All drives in the RAID 5 array.

3. RAID Controller Failure

The RAID controller manages the striping and parity operations for RAID 5 arrays. If the controller fails, the array may become unreadable, even if the drives themselves are functional.

  • Symptoms: RAID array not detected, controller errors, system unable to boot into the RAID configuration, or incorrect RAID status.
  • Causes: Power surges, controller hardware failure, or firmware corruption.
  • Drives Affected: All drives connected to the failed RAID controller.

4. Logical or Software Failure

Logical failures affect the file system, RAID metadata, or partition table, making the data inaccessible even though the hardware is operational.

  • Symptoms: Missing files, corrupted data, array showing as unformatted, or error messages when accessing the RAID array.
  • Causes: File system corruption, accidental formatting, RAID configuration errors, or partition table damage.
  • Drives Affected: All drives in the RAID 5 array.

5. Parity Corruption

Parity corruption occurs when the parity data used to rebuild the array becomes damaged, rendering it impossible to reconstruct the data when a drive fails.

  • Symptoms: Data corruption, failed RAID rebuilds, or degraded array performance.
  • Causes: Firmware issues, improper RAID management, or power outages during parity writes.
  • Drives Affected: All drives in the RAID 5 array.

Steps to Take if Your RAID 5 Array Fails

If your RAID 5 array fails, it’s important to take steps to prevent further data loss and increase the chances of a successful recovery:

  1. Do Not Attempt to Rebuild the Array: Rebuilding the RAID 5 array without expertise can lead to further corruption or data loss.
  2. Power Down the System: If you suspect a failure, immediately shut down the system to avoid damaging the array further.
  3. Avoid DIY Recovery Software: RAID 5 is complex, and using free recovery tools can overwrite parity data, making recovery impossible.
  4. Contact a Professional RAID Recovery Service: Reach out to a service that specialises in RAID 5 recovery to assess the situation and begin the recovery process.

Professional RAID 5 Hard Drive Recovery Services

RAID 5 recovery involves reconstructing the array using parity data and recovering data from any failed drives. Our Professional RAID recovery services use specialised Raid recovery tools and expertise to recover lost data while preserving the integrity of the RAID array.

1. Data Recovery from Failed RAID 5 Drives

If one or more drives in a RAID 5 array have failed, our raid engineers can rebuild the array using the remaining drives and the parity data. If multiple drives have failed, advanced recovery techniques are used.

  • Parity Reconstruction: Raid Engineers use parity data to reconstruct the missing data from the failed drives.
  • Multiple Drive Recovery: In cases where multiple drives have failed, Raid Engineers recover as much data as possible from the remaining functional drives and rebuild the array.

2. Physical Drive Repair in a Cleanroom Environment

If a drive in the RAID 5 array has experienced mechanical failure, such as a head crash, spindle motor failure, or physical damage, Raid Engineers perform repairs in a clean environment to recover the data.

  • Head Replacement: Damaged read/write heads are replaced with compatible donor parts to access data.
  • Spindle Motor Repair: If the spindle motor fails, it is repaired or replaced to restore drive functionality.
  • Platter Recovery: Data can be extracted directly from the platters, even if other components have failed.

3. Logical Data Recovery

For logical failures, such as file system corruption, accidental formatting, or partition table damage, professional recovery services use advanced tools to repair the logical structure and restore data.

  • File System Repair: Corrupted file systems are repaired to allow access to lost files.
  • RAID Metadata and Partition Repair: Raid Engineers repair corrupted RAID metadata or partition tables to restore the RAID 5 array configuration.

4. RAID Controller Repair

If the RAID 5 failure is caused by a controller malfunction, professionals can repair or replace the controller to restore access to the array.

  • Controller Diagnostics and Repair: Raid Engineers diagnose the RAID controller and either repair it or replace it with a compatible model.
  • Firmware Repair: Corrupted RAID controller firmware is repaired or reflashed to restore the array.

5. RAID 5 Rebuild Assistance

If the RAID 5 array was in the middle of a rebuild when the failure occurred, we can assist in completing the rebuild without data loss.

  • Rebuild Interruption Recovery: Recovery specialists recover data from arrays that failed during rebuilds or synchronisation processes.
  • Incomplete RAID Rebuild Repair: In cases where the rebuild was incomplete, recovery services can repair the array and restore data integrity.

Contact Us

Tell us about your issue and we'll get back to you.